ADA Shower Requirements Checker
Enter the finished inside size and the fixtures. Each rule shows its section of the 2010 ADA Standards for Accessible Design.
Checks a subset of the 2010 ADA Standards (§§ 608–610). The Standards bind public accommodations and commercial facilities, not private homes; local codes and the Fair Housing Act design rules may also apply. Not legal advice.
The three ADA shower types
| Type | Clear inside size | Entry | Section |
|---|---|---|---|
| Transfer | exactly 36 × 36 in | 36 in wide min, plus 36 × 48 in clearance outside | 608.2.1 |
| Standard roll-in | 30 in wide × 60 in deep min | 60 in wide min (the open long side) | 608.2.2 |
| Alternate roll-in | 36 × 60 in min | 36 in at one end of the long side | 608.2.3 |
Other requirements
- Threshold: ½ in max in roll-in showers; in transfer showers ½ in max, beveled, rounded or vertical – 2 in allowed in existing buildings where ½ in would disturb the slab reinforcement (608.7).
- Grab bars: horizontal, 33–36 in above the floor to the top of the gripping surface (609.4); round bars 1¼–2 in outside diameter (609.2.1). In a transfer shower across the control wall and the back wall to 18 in from the control wall (608.3.1); in a standard roll-in with a seat on the back wall and the wall opposite the seat, not above the seat; without a seat on three walls (608.3.2).
- Hand shower: hose at least 59 in, usable as a fixed head too, with a non-positive shut-off; water no hotter than 120 °F (608.6).
- Controls: transfer – on the wall opposite the seat, 38–48 in above the shower floor, within 15 in of the seat centerline toward the opening (608.5.1); standard roll-in – above the grab bar but no higher than 48 in (608.5.2).
- Seat: top 17–19 in above the bathroom floor; folding in roll-in showers; it must hold 250 lb (610.3, 610.4).
Does this apply to my house?
The ADA Standards apply to public accommodations and commercial facilities. A private single-family home is not required to meet them. They are still the most widely used, measurable design reference for an accessible shower, and an occupational therapist or a VA grant reviewer may use them. Multifamily housing can fall under the Fair Housing Act and local accessibility codes instead.
Price an accessible layout with the curbless shower cost calculator or the tub to shower conversion calculator.
Questions
What size is an ADA shower?
A transfer shower is 36 × 36 inches; a standard roll-in shower at least 30 × 60 inches with a 60-inch opening; an alternate roll-in at least 36 × 60 inches (2010 ADA Standards § 608.2).
What height are ADA shower grab bars?
33 to 36 inches above the finished floor, measured to the top of the gripping surface (§ 609.4).
What is the maximum threshold for an ADA shower?
½ inch in roll-in showers. Transfer showers also ½ inch, with up to 2 inches allowed in existing buildings where a lower threshold would disturb the slab reinforcement (§ 608.7).
Sources
- U.S. Department of Justice – 2010 ADA Standards for Accessible Design, §§ 608 (shower compartments), 609 (grab bars), 610 (seats) (2010 Standards, page checked 2026-11-28)
Get quotes from local bathroom remodelers
Send the estimate from this page to remodelers near you and compare written quotes on the same scope. Your last estimate is attached automatically.
- Ask each remodeler to quote the same items: demolition, base, walls, waterproofing, valve, glass, permit.
- Ask what happens if they find rot or mold behind the tub – and at what price.
- Check the contractor's license with your state board where one is required, and their insurance.
- We are building our remodeler network ZIP by ZIP. If no one covers your area yet, we say so by e-mail.